CS计算机代考程序代写 Wind Turbine Data

Wind Turbine Data
Wind Power Generator Parameters
The mechanical power of the wind turbine can be calculated from equation (1) while the power coefficient is given in (2) and (3). The parameters for the different turbines are shown on pages 2, 3, and 4, the same power coefficient equation should be used for all the different projects. If you have already used another set of generator parameters and power coefficient this is OK but please reference where you have got them from.
() ()()
,,,,,
(1) (2)
(3)
where
Page 1 of 4

DFIG Motor Parameters
Based on [1]
Wind Turbine
Parameter
Value
Rated Power
1.5MW
Blade Radius (m)
35
Rated Speed (rpm)
24.44
Rated Torque (Nm)
585,938
Minimum Wind Speed (m/s)
4.8
Rated Wind Speed (m/s)
11
Maximum Wind Speed (m/s)
25
Gear Box Ratio
71.6
Shaft Stiffness Coefficient ( ) (Nm)
503,671,633
Shaft Damping Coefficient ( ) (Nm/s)
17,580,162
Shaft Stiffness Coefficient ( ) (Nm)
7,034,520
Shaft Damping Coefficient ( ) (Nm/s)
245,533
Inertia (Kg/m2)
3,210,488
Generator
Parameter
Value
Rated Mechanical Power
1.5MW
Rated Stator line-line voltage (V)
690
Pole Number
4
Rated Stator Frequency (Hz)
50
Rated Rotor Speed (rpm)
1750
Maximum Rotor Speed (rpm)
1950
Nominal Rotor Speed Range (rpm)
750-1750
Rated Slip
-0.1667
Rated Mechanical Torque (Nm)
8183.5
Stator Resistance (Ohms)
0.00265
Rotor Resistance (Ohms)
0.00263
Stator Leakage Inductance (mH)
0.1687
Rotor Leakage Inductance (mH)
0.1337
Mutual Inductance (mH)
5.4749
Inertia (Kg/m2)
60
Page 2 of 4

PMSG Parameters
Based on [2, 3]
Wind Turbine
Parameter
Value
Rated Power
315kW
Blade Radius (m)
15
Rated Speed (rpm)
59.4
Rated Torque (Nm)
50,643
Minimum Wind speed (m/s)
4
Maximum Wind Speed (m/s)
25
Shaft Stiffness Coefficient ( ) (Nm)
43,532,665
Shaft Damping Coefficient ( ) (Nm/s)
1,519,465
Inertia (Kg/m2)
90,632
Generator
Parameter
Value
Rated Mechanical Power
315kW
Rated Stator line-line voltage (V)
415
Pole Number
96
Stator Resistance (Ohms)
0.0054
Stator Inductance (mH)
0.9
Mutual Inductance (mH)
0.54
Stator Flux (Wb)
1.3
Inertia (Kg/m2)
50
Page 3 of 4

SCIG Parameters
Based on [2, 3]
Wind Turbine
Parameter
Value
Rated Mechanical Power
250KW
Blade Radius (m)
15
Rated Speed (rpm)
55
Rated Torque (Nm)
43,403
Minimum Wind speed (m/s)
4
Rated Wind Speed (m/s)
10.65
Maximum Wind Speed (m/s)
25
Gear Box Ratio
33.6
Shaft Stiffness Coefficient ( ) (Nm)
37,309,169
Shaft Damping Coefficient ( ) (Nm/s)
1,302,240
Shaft Stiffness Coefficient ( ) (Nm)
1,110,430
Shaft Damping Coefficient ( ) (Nm/s)
38,759
Inertia (Kg/m2)
68,681
Generator
Parameter
Parameter
Rated Mechanical Power
250KW
Rated Stator line- line voltage (V)
415
Pole Number
4
Rated Stator Frequency (Hz)
60
Rated Synchronous Speed (rpm)
1800
Rated Slip at Rated Speed
-0.02667
Stator Resistance (Ohms)
0.016
Rotor Resistance (Ohms)
0.015
Stator Leakage Inductance (mH)
0.374
Rotor Leakage Inductance (mH)
0.411
Mutual Inductance (mH)
14.143
Inertia (Kg/m2)
50
[1] B. Wu, Y. Lang, N. Zargari, and S. Kouro, Power Conversion and Control of Wind Energy Systems: John Wiley & Sons, 2011.
[2] K. Ohyama, T. Sakamoto, S. Arinaga, and Y. Yamashita, “Simulation of Variable-Speed Wind Generation System Using Boost Converter of Permanent Magnet Synchronous Generator,” Electrical Engineering in Japan, vol. 169, pp. 37-54, 2009.
[3] K. Ohyama, S. Arinaga, and T. Shigemizu, “Sensorless Vector Controlled Converter for Variable Speed Wind Generation System Using an Induction Generator,” Electrical Engineering in Japan, vol. 159, pp. 62-75, 2007.
Page 4 of 4